4Sludge heating/mixing tanks 435 L Rated consumption Dimensions Heating by steam, Heating by Circ. Pump thermal oil el. power El. power L x W x H mm kg Type 435 l 50 kg/h – 7-10 bar 12 kW 2,5 kW 1528 x 905 x 1767 370 700 l 50 kg/h – 7-10 bar 12 kW 2,5 kW 1422 x 836 x 2016 500 1100 l 50 kg/h – 7-10 bar 12 kW 2,5 kW 1632 x 1251 x 2050 500 1700 l 50 kg/h – 7-10 bar 16 kW 2,5 kW 1905 x 1439 x 2110 590 2000 l 50 kg/h – 7-10 bar 16 kW 2,5 kW 1815 x 1439 x 2360 630 3000 l 50 kg/h – 7-10 bar 16 kW 2,5 kW 2030 x 1660 x 2470 750 400 l Diesel Oil Tank 910 x 750 x 1167 190 4351 Water Service Tank (12 kW) 1528 x 846 x 2308 491 Sludge Preparation Tank For most economical operation and optimal efficiency of the incinerating plant we recommend installing two sludge tanks allowing for proper water settling and drainage. One tank is used for settling and the second one is the service tank. All TeamTec tanks are complete with sludge circulation pump, level switches and thermostat. Other optional items available. Heating options: •steam •electric •thermal oil •super heated water Optional supplements: • TeamTec water in oil monitor for a perfect control of your sludge oil quality, available upon request. • Level gauge for read out on incinerator display 42000 L 41100 L 4700 L Insulated and plated version